P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax:     (440) 729-8238

Radiation Therapy
   3-D Water Phantom Dosimetry
   Waste Monitors
   ADCL Calibrations
   Area Monitors
   Barometers-Thermometers-Accessories
   Block-Mold Room
   CT Electron Density Phantom
   Digital Portal Imaging
   Electrometers
   HDR-LDR Accessories
   IMRT QA Equipment
   Ion Chambers
   Linac Daily Output QA Devices
   Patient Dose Verification System
   Radiation Survey Meters
   Room Lasers
   Sensitometers-Desensitometers
   Superficial and Orthovoltage Radiotherapy Equipment
   TG-51 Water Phantom
   Triax Cable Reels
   Triax Extension Cables
   Water Equivalent Phantoms
Diagnostic Radiology
   Calibration Services
   Multi Function Meters
   Radiation Protection-Monitoring
   Test Patterns-Accessories
   Test Phantoms
Radiation Safety-Homeland Security
   Detectors
   Digital Portal Imaging
   Gate Monitors
   Handheld Survey Meters
   Personal Dosimeters
   Portal Monitor
   Radiation Simulation-Training
   Response Kits
Nuclear Medicine
   Dose Calibrators
   Lead Shielding
   Thyroid Uptake System


Thyroid Uptake System : Atomlab 950
 Atomlab 950 The Atomlab 950 Thyroid Uptake System is an advanced multi-purpose spectrum analysis instrument designed for diverse nuclear medicine applications. Uptake studies, bioassays, Schilling tests, hematology tests, wipe tests, and other user-defined tasks are accomplished with speed and precision using this fully integrated computer-controlled instrument and its comprehensive selection of application software. The system’s multichannel analyzer has 1024 channels, with separate input connections for the probe and optional well counter. Engineered for portability, durability, and operational efficiency, the Atomlab 950 handles clinical tests, safety compliance tasks, and system administration procedures quickly and accurately. Task-specific software provides step-by-step guidance throughout all procedures, automatically performs calculations, stores patient information and test results, and outputs clear, concise reports. The “Procedure Definition” screen is used to set up a facility’s standardized test protocols by selecting the most appropriate program, editing program parameters to suit specific facility requirements, or by creating an entirely new procedure. When program design or modification is completed, the new program is stored for future use. A toolbar “help” button provides detailed system assistance.

The self-contained Atomlab 950 system is configured on a mobile platform with locking casters and a base that measures only 30" by 31.5" (76 x 80 cm). An upper shelf supports the computer, monitor, keyboard, and trackball mouse. A lower shelf supports the color inkjet printer. The base of the stand incorporates a shelf to hold the optional well counter. A 2" x 2" NaI(Tl) detector with collimator articulates on a counterbalanced arm. Twenty-two inches (56 cm) of vertical travel allows the probe to be positioned up to 55" (140 cm) from the floor to accommodate seated or supine patients. The probe swings more than 180° on the horizontal plane, and extends outward up to approximately 34" (86 cm) from the support column. This design makes positioning for uptake studies simple and comfortable for both patient and technologist.

Thyroid Uptake System
– Powerful graphics
– Easy to use software
– Easy to read, attractive reports
– Add your own comments
– Custom patient worksheet
– 23 Pre-selected isotopes
– Unlimited user defined isotopes

1024 Channel Multi-Channel Analyzer

Thyroid Uptake Program
– Multiple uptake measurements
– Memory for unlimited number of patients
– Automatic decay correction or recount of a standard
– Choose manual or auto-count time
– User defined protocols
– On-line spectrum analysis
– Automatic result calculations
– Normal range(s) included on report
– Referring physician’s report

Wipe Test Program
– Meets regulatory requirements
– Location wipes reported in choice of dpm, µCi, kBq
– Sealed source wipes reported in choice of dpm, µCi, kBq
– Customized setup to department needs
– Incoming shipments easily recorded
– Quick isotope identification

Bioassay Program
– Two report formats: individual and employee summary
– Bioassay any isotope

Schilling Test Program
– For Mallinckrodt, Bracco, and Nycomed/Amersham (Dicopac) kits

Hematology Program
– Red blood cell survival
– Blood volume for Cr-51 and I-125
– ERPF and GFR

Administration / QA Program
– Automatic high-voltage adjustment
– Automatic daily calibration
– Automatic Chi-Square
– Automatic test of communication
– Isotope efficiency calculations
– Complete spectral analysis

Manual MCA Program
– Familiar spectrometer functions
– Counts in: Preset time, preset ROI counts, continuous counting
– Count and list for manual calculations with set ROI
– Spectrum analysis with multiple ROIs
– Versatile enough for any manual protocol

Click Here to Download a Printable Information Sheet. (.pdf format)
 
PH 1-800-795-5226 FAX 440-729-8238
P.O. Box 666 Chesterland, OH 44026


Site created & maintained by
Tux Studios.Com

© LACO Online, Chesterland, Ohio



 Other Products

 Veridose
More Info

 

 Tracker™ Model 90100
More Info

 

 CIRS Model 002HN IMRT Head and Neck Phantom
More Info