P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax: (440) 729-8238
Radiation Therapy
3-D Water Phantom Dosimetry
ADCL Calibrations
Area Monitors
Barometers-Thermometers-Accessories
Block-Mold Room
CT Electron Density Phantom
Digital Portal Imaging
Electrometers
HDR-LDR Accessories
IMRT QA Equipment
Ion Chambers
Linac Daily Output QA Devices
Patient Dose Verification System
Radiation Survey Meters
Room Lasers
Sensitometers-Desensitometers
TG-51 Water Phantom
Triax Cable Reels
Triax Extension Cables
Water Equivalent Phantoms
Diagnostic Radiology
Calibration Services
Diagnostic Test Tools
Multi Function Meters
Radiation Protection-Monitoring
Test Patterns-Accessories
Test Phantoms
Radiation Safety-Homeland Security
Detectors
Digital Portal Imaging
Gate Monitors
Handheld Survey Meters
Personal Dosimeters
Portal Monitor
Radiation Simulation-Training
Response Kits
Waste Monitors
Nuclear Medicine
Dose Calibrators
Lead Shielding
Thyroid Uptake System
Thyroid Uptake System :
Atomlab 930
Atomlab 930 Thyroid Uptake System
The
Atomlab 930
is a versatile and cost- effective spectrum analysis system for performing uptake studies, bioassays, Schilling tests, wipe tests, and other user-defined tasks in the nuclear medicine environment. Engineered for portability, durability, and efficiency, the 930 handles an array of clinical tests, safety compliance tasks, and system administration/QA procedures. A powerful microprocessor guides the user through procedures, automatically performs necessary calculations, and outputs clear, concise reports. The system's internal memory stores results on up to twenty-five patients (up to four studies per patient).
The self-contained 930 system is configured on a mobile platform with locking casters and a base that measures only 30" by 31.5" (76 x 80 cm). A 2-tiered shelf supports the microprocessor/ keyboard and printer. The base of the stand has a special shelf to hold an optional well counter. 2" x 2" NaI(Tl) detector with collimator articulates on a counterbalanced arm. Twenty-two inches (56 cm) of vertical travel allows the probe to be positioned up to 55" (140 cm) from the floor to accommodate seated or supine paients. The probe swings more than 180° on the horizontal plane, and extends outward up to approximately 34" (86 cm) from the support column. This design makes positioning for uptake studies simple and comfortable for both patient and technologist, and allows the unit to be easily moved for a variety of applications or storage. The system's multi-channel analyzer has 256 channels, with separate inputs connections for the probe and optional well counter. The system's embedded software has specialized programs for thyroid uptake, bioassay, wipe test, Schilling test, manual (user-defined) rate counts, system administration and quality assurance, and start-up self test. Programs print out concise, easily interpreted reports.
The Table Top System is self-contained, requiring a minimal amount of counterspace. The 256 channel MCA is built into the Atomlab 930.
Click Here to Download a Printable Information Sheet. (.pdf format)
PH 1-800-795-5226
FAX 440-729-8238
P.O. Box 666 Chesterland, OH 44026
Site created & maintained by
Tux Studios.Com
© LACO Online, Chesterland, Ohio
Advanced Search
Other Products
Solid Water®
More Info
Model L-600 Fluoroscopic Device
More Info
Unfors Xi Platinum Plus
More Info