P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax: (440) 729-8238
Radiation Therapy
3-D Water Phantom Dosimetry
ADCL Calibrations
Area Monitors
Barometers/Thermometers/Accessories
Block/Mold Room
CT Electron Density Phantom
Digital Portal Imaging
Electrometers
HDR/LDR Accessories
IMRT QA Equipment & Software
Ion Chambers
Linac Daily Output QA Devices
Patient Dose Verification System
Radiation Survey Meters
Room Lasers
Sensitometers/Desensitometers
TG-51 Water Phantom
Triax Cable Reels
Triax Extension Cables
Water Equivalent Phantoms
Diagnostic Radiology
Calibration Services
Multi Function Meters
Test Patterns/Accessories
Test Phantoms
Radiation Safety/Homeland Security
Gate Monitors
Handheld Survey Meters
Personal Dosimeters
Portal Monitor
Radiation Simulation/Training
Response Kits
Waste Monitors
Nuclear Medicine
Dose Calibrators
Thyroid Uptake System
Patient Dose Verification System :
SUN Nuclear QED™
The SUN Nuclear QED™ features a flat design for easy patient placement. It is ideal for treatments where diode placement is normal to the beam. QED’s are available in three photon energy ranges, and a single range for all electron energies.
The SUN Nuclear Applications
QED™ diode detectors should be used in situations where the beam is normal or close to normal to the patient skin surface.
Energy Ranges
– choosing the right QED™ QED™ detectors are offered in three photon energy ranges, a single electron energy range, and a skin detector.
a) P/N 1114000-0 1-4 MV
b) P/N 1115000-0 6-12 MV
c) P/N 1116000-0 15-25 MV
d) P/N 1112000-0 electron energies
e) P/N 1113000-0 Skin (no buildup)
Accuracy
The QED™ offers exceptional accuracy for a flat diode detector. When tested on top of 6 cm of virtual water, variation in directional response is +/- 0.5% for 30°, and +/- 1.0% for 45° for 6MV beams.
Features
Flat design allows for easy and reliable placement on patient skin surface
Advanced p-type die design is accurate and responsive
Compatibility with any diode based dosimetry system
Long lifetime if handled properly
Intelligent pricing
QED™ features a flat design for easy patient placement. It is ideal for treatments where diode placement is normal to the beam. QED’s are available in three photon energy ranges, and a single range for all electron energies.
Click Here to Download a Printable Information Sheet. (.PDF format)