P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax:     (440) 729-8238

Radiation Therapy
  3-D Water Phantom Dosimetry
  ADCL Calibrations
  Area Monitors
  Barometers/Thermometers/Accessories
  Block/Mold Room
  CT Electron Density Phantom
  Digital Portal Imaging
  Electrometers
  HDR/LDR Accessories
  IMRT QA Equipment & Software
  Ion Chambers
  Linac Daily Output QA Devices
  Patient Dose Verification System
  Radiation Survey Meters
  Room Lasers
  Sensitometers/Desensitometers
  TG-51 Water Phantom
  Triax Cable Reels
  Triax Extension Cables
  Water Equivalent Phantoms
Diagnostic Radiology
  Calibration Services
  Multi Function Meters
  Test Patterns/Accessories
  Test Phantoms
Radiation Safety/Homeland Security
  Gate Monitors
  Handheld Survey Meters
  Personal Dosimeters
  Portal Monitor
  Radiation Simulation/Training
  Response Kits
  Waste Monitors
Nuclear Medicine
  Dose Calibrators
  Thyroid Uptake System


Patient Dose Verification System : SUN Nuclear QED™
SUN Nuclear QED™ The SUN Nuclear QED™ features a flat design for easy patient placement. It is ideal for treatments where diode placement is normal to the beam. QED’s are available in three photon energy ranges, and a single range for all electron energies.

The SUN Nuclear Applications
QED™ diode detectors should be used in situations where the beam is normal or close to normal to the patient skin surface.
Energy Ranges – choosing the right QED™ QED™ detectors are offered in three photon energy ranges, a single electron energy range, and a skin detector.
a) P/N 1114000-0    1-4 MV
b) P/N 1115000-0    6-12 MV
c) P/N 1116000-0    15-25 MV
d) P/N 1112000-0    electron energies
e) P/N 1113000-0    Skin (no buildup)

Accuracy
The QED™ offers exceptional accuracy for a flat diode detector. When tested on top of 6 cm of virtual water, variation in directional response is +/- 0.5% for 30°, and +/- 1.0% for 45° for 6MV beams.

Features
  • Flat design allows for easy and reliable placement on patient skin surface
  • Advanced p-type die design is accurate and responsive
  • Compatibility with any diode based dosimetry system
  • Long lifetime if handled properly
  • Intelligent pricing

    QED™ features a flat design for easy patient placement. It is ideal for treatments where diode placement is normal to the beam. QED’s are available in three photon energy ranges, and a single range for all electron energies.

    Click Here to Download a Printable Information Sheet. (.PDF format)
  •  
    PH 1-800-795-5226 FAX 440-729-8238
    P.O. Box 666 Chesterland, OH 44026


    Site created & maintained by
    Tux Studios.Com

    © LACO Online, Chesterland, Ohio



    Advanced

     Other Products

     Gemini Patient Alignment Lasers
    More Info

     

     Simulated Radiation Probe Paks
    More Info

     

     Iso-align™
    More Info