P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax: (440) 729-8238
Radiation Therapy
3-D Water Phantom Dosimetry
ADCL Calibrations
Area Monitors
Barometers/Thermometers/Accessories
Block/Mold Room
CT Electron Density Phantom
Digital Portal Imaging
Electrometers
HDR/LDR Accessories
IMRT QA Equipment & Software
Ion Chambers
Linac Daily Output QA Devices
Patient Dose Verification System
Radiation Survey Meters
Room Lasers
Sensitometers/Desensitometers
TG-51 Water Phantom
Triax Cable Reels
Triax Extension Cables
Water Equivalent Phantoms
Diagnostic Radiology
Calibration Services
Multi Function Meters
Test Patterns/Accessories
Test Phantoms
Radiation Safety/Homeland Security
Gate Monitors
Handheld Survey Meters
Personal Dosimeters
Portal Monitor
Radiation Simulation/Training
Response Kits
Waste Monitors
Nuclear Medicine
Dose Calibrators
Thyroid Uptake System
Response Kits :
Model 14CRK Response Kit
Ludlum
Model 14 CRK Response Kit
PART NUMBER:48-2653
DETECTORS:
Model 44-9 Pancake G-M, Model 44-2 Gamma Scintillator (
others available
)
METER DIAL:
Typically 0 - 2 mR/hr and 6.8k cpm, BAT TEST (
others available
)
MULTIPLIERS:
X0.1, X1, X10, X100, X1000
LINEARITY:
Reading within plus or minus 10% of true value with detector connected
CONNECTOR:
Series “C” (
others available
)
INTERNAL DETECTOR:
Energy compensated G-M (
used with X1000 scale only
)
ENERGY RESPONSE:
Within plus or minus 15% of true value between 60 keV - 3 MeV (
internal detector only
)
THRESHOLD:
30 mV plus or minus 10 mV
AUDIO:
Built in unimorph speaker with ON/OFF switch (
greater than 60 dB at 2 feet
)
CALIBRATION CONTROLS:
Accessible from front of instrument (
protective cover provided
)
HIGH VOLTAGE:
900 volts
THRESHOLD:
30 mV plus or minus 10 mV
RESPONSE:
Toggle switch for FAST (4 seconds) or SLOW (22 seconds) from 10% to 90% of final reading
RESET:
Push-button to zero meter
POWER:
2 each “D” cell batteries (
housed in sealed compartment that is externally accessible
)
BATTERY LIFE:
Typically 600 hours with alkaline batteries (
battery condition can be checked on meter
)
METER:
2.5" (6.4 cm) arc, 1 mA analog type
CONSTRUCTION:
Cast and drawn aluminum with beige polyurethane enamel paint
TEMPERATURE RANGE:
-4° F(-20° C) to 122° F(50° C) May be certified for operation from -40° F(-40° C) to 150° F(65° C)
SIZE:
6.5" (16.5 cm)H X 3.5" (8.9 cm)W X 8.5" (21.6 cm)L
WEIGHT:
3.5 lbs (1.6 kg) including batteries
5 Range Survey Meter
Internal High Range G-M Detector
Alpha Beta Gamma Pancake G-M
1" X 1" NaI(Tl) Gamma Scintillator
Check Source
Total Range from 0 - 2000 mR/hr
Click Here to Download a Printable Information Sheet. (.PDF format)
PH 1-800-795-5226
FAX 440-729-8238
P.O. Box 666 Chesterland, OH 44026
Site created & maintained by
Tux Studios.Com
© LACO Online, Chesterland, Ohio
Advanced
Other Products
Gemini Patient Alignment Lasers
More Info
Model 375-30 Waste Monitor
More Info
Model 52-1 Portable Portal Monitor
More Info