P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax:     (440) 729-8238

Radiation Therapy
  3-D Water Phantom Dosimetry
  ADCL Calibrations
  Area Monitors
  Barometers/Thermometers/Accessories
  Block/Mold Room
  CT Electron Density Phantom
  Digital Portal Imaging
  Electrometers
  HDR/LDR Accessories
  IMRT QA Equipment & Software
  Ion Chambers
  Linac Daily Output QA Devices
  Patient Dose Verification System
  Radiation Survey Meters
  Room Lasers
  Sensitometers/Desensitometers
  TG-51 Water Phantom
  Triax Cable Reels
  Triax Extension Cables
  Water Equivalent Phantoms
Diagnostic Radiology
  Calibration Services
  Multi Function Meters
  Test Patterns/Accessories
  Test Phantoms
Radiation Safety/Homeland Security
  Gate Monitors
  Handheld Survey Meters
  Personal Dosimeters
  Portal Monitor
  Radiation Simulation/Training
  Response Kits
  Waste Monitors
Nuclear Medicine
  Dose Calibrators
  Thyroid Uptake System


Response Kits : Model 14CRK Response Kit
Model 14CRK Response Kit Ludlum
Model 14 CRK Response Kit
PART NUMBER:48-2653

DETECTORS: Model 44-9 Pancake G-M, Model 44-2 Gamma Scintillator (others available)
METER DIAL:Typically 0 - 2 mR/hr and 6.8k cpm, BAT TEST (others available )
MULTIPLIERS: X0.1, X1, X10, X100, X1000
LINEARITY: Reading within plus or minus 10% of true value with detector connected
CONNECTOR: Series “C” (others available )
INTERNAL DETECTOR: Energy compensated G-M (used with X1000 scale only )
ENERGY RESPONSE: Within plus or minus 15% of true value between 60 keV - 3 MeV (internal detector only )
THRESHOLD: 30 mV plus or minus 10 mV
AUDIO: Built in unimorph speaker with ON/OFF switch (greater than 60 dB at 2 feet )
CALIBRATION CONTROLS: Accessible from front of instrument (protective cover provided )
HIGH VOLTAGE:900 volts
THRESHOLD: 30 mV plus or minus 10 mV
RESPONSE: Toggle switch for FAST (4 seconds) or SLOW (22 seconds) from 10% to 90% of final reading
RESET: Push-button to zero meter
POWER: 2 each “D” cell batteries (housed in sealed compartment that is externally accessible )
BATTERY LIFE: Typically 600 hours with alkaline batteries (battery condition can be checked on meter )
METER: 2.5" (6.4 cm) arc, 1 mA analog type
CONSTRUCTION: Cast and drawn aluminum with beige polyurethane enamel paint
TEMPERATURE RANGE: -4° F(-20° C) to 122° F(50° C) May be certified for operation from -40° F(-40° C) to 150° F(65° C)
SIZE: 6.5" (16.5 cm)H X 3.5" (8.9 cm)W X 8.5" (21.6 cm)L
WEIGHT: 3.5 lbs (1.6 kg) including batteries
  • 5 Range Survey Meter
  • Internal High Range G-M Detector
  • Alpha Beta Gamma Pancake G-M
  • 1" X 1" NaI(Tl) Gamma Scintillator
  • Check Source
  • Total Range from 0 - 2000 mR/hr


  • Click Here to Download a Printable Information Sheet. (.PDF format)
     
    PH 1-800-795-5226 FAX 440-729-8238
    P.O. Box 666 Chesterland, OH 44026


    Site created & maintained by
    Tux Studios.Com

    © LACO Online, Chesterland, Ohio



    Advanced

     Other Products

     Gemini Patient Alignment Lasers
    More Info

     

     Model 375-30 Waste Monitor
    More Info

     

     Model 52-1 Portable Portal Monitor
    More Info