P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax: (440) 729-8238
Radiation Therapy
3-D Water Phantom Dosimetry
Waste Monitors
ADCL Calibrations
Area Monitors
Barometers-Thermometers-Accessories
Block-Mold Room
CT Electron Density Phantom
Digital Portal Imaging
Electrometers
HDR-LDR Accessories
IMRT QA Equipment
Ion Chambers
Linac Daily Output QA Devices
Patient Dose Verification System
Radiation Survey Meters
Room Lasers
Sensitometers-Desensitometers
Superficial and Orthovoltage Radiotherapy Equipment
TG-51 Water Phantom
Triax Cable Reels
Triax Extension Cables
Water Equivalent Phantoms
Diagnostic Radiology
Calibration Services
Multi Function Meters
Radiation Protection-Monitoring
Test Patterns-Accessories
Test Phantoms
Radiation Safety-Homeland Security
Detectors
Digital Portal Imaging
Gate Monitors
Handheld Survey Meters
Personal Dosimeters
Portal Monitor
Radiation Simulation-Training
Response Kits
Nuclear Medicine
Dose Calibrators
Lead Shielding
Thyroid Uptake System
Portal Monitor :
Model 52-1 Portable Portal Monitor
Ludlum
Model 52-1
PART NUMBER:48-3172
Portable
Plastic Scintillation Detectors
Assembles or Disassembles in less than 5 Minutes
Carrying Case Included
INDICATED USE:
Portable personnel monitoring (NOTE:
This instrument is portable and can be assembled or disassembled in less than 5 minutes. Carrying case is included
)
DETECTORS:
4 ea. 168 cubic inch plastic scintillation allowing a total detection area of 672 cubic inches
THRESHOLD:
4 plus or minus 1 mV
DISPLAY:
2 line X 20 character LCD shows background rates from all detectors, and sigma values above background.
ALARM:
Indicated by red LED, and audible signal (
greater than 60 dB at 2 feet
)
COUNT TIME:
Adjustable from 0 - 20 seconds (
0 second setting is for walk through mode
)
ENTER/CHECKING:
(
green LED
) Indicates system is ready for use. Flashing LED indicates a count is in progress.
INCOMPLETE/UPDATING:
(
amber LED
) Indicates the user has stepped out of the portal before counting was completed, or that an update is in progress.
FAILURE:
(
red LED
) Indicates a high or low background
INFRARED SENSOR:
A retro-reflective sensor senses portal occupancy
PARAMETERS:
All parameters are stored in non-volatile memory
OUTPUT:
RS-232 and relay output connectors located on the bottom of the electronics chassis
POWER:
85 - 250 VAC, 50 - 60 Hz single phase (
less than 100 mA
); or 3 ea. “D” cell batteries.
BATTERY LIFE:
Typically 24 hours in a non-alarm condition
Click Here to Download a Printable Information Sheet. (.PDF format)
PH 1-800-795-5226
FAX 440-729-8238
P.O. Box 666 Chesterland, OH 44026
Site created & maintained by
Tux Studios.Com
© LACO Online, Chesterland, Ohio
Advanced Search
Other Products
Model 12-4 Neutron Counter
More Info
CIRS CT Dose Phantom
More Info
Veridose
More Info