Radiation Therapy
3-D Water Phantom Dosimetry
ADCL Calibrations
Area Monitors
Barometers/Thermometers/Accessories
Block/Mold Room
CT Electron Density Phantom
Digital Portal Imaging
Electrometers
HDR/LDR Accessories
IMRT QA Equipment & Software
Ion Chambers
Linac Daily Output QA Devices
Patient Dose Verification System
Radiation Survey Meters
Room Lasers
Sensitometers/Desensitometers
TG-51 Water Phantom
Triax Cable Reels
Triax Extension Cables
Water Equivalent Phantoms
Diagnostic Radiology
Calibration Services
Multi Function Meters
Test Patterns/Accessories
Test Phantoms
Radiation Safety/Homeland Security
Gate Monitors
Handheld Survey Meters
Personal Dosimeters
Portal Monitor
Radiation Simulation/Training
Response Kits
Waste Monitors
Nuclear Medicine
Dose Calibrators
Thyroid Uptake System
HDR/LDR Accessories :
HDR 1000 Plus Well Chamber
The Standard Imaging
HDR 1000 Plus Well Chamber
, precisely calibrates radioactive sources used for cancer treatment. The HDR 1000 Plus is the standard instrument for independently verifying prescribed patient dose. The verification helps protect the hospital from misadministration and liability. The HDR 1000 Plus is an air communicating chamber so there is no inaccuracy due to an undetected gas leak as in a pressurized chamber. Performance of the HRD 1000 Plus has been
validated in over 30 publications.
The HDR 1000 Plus is ideal for low dose rate and high dose rate brachytherapy. Source holders are available for most existing isotopes available on the market today.
Advantages of the HDR 1000 Plus Ion Chamber
Easy to use:
No complicated set-up or lengthy procedure.
Stable:
Short term stability, within +/-0.02% for ten insertions. One to two year re-calibrations average within 0.2% of original calibration.
Confidence:
Corrections are built in, requiring only the application of the ADCL calibration factor.
Aion:
Ion collection efficiency is 1.000 with sources ranging from 0.1 mCi to greater than 20 Ci. If you have a different chamber with a lower collecting efficiency the response is not linear at activities other than the calibration point, and your accuracy may suffer.
Response:
0.1% over 1 cm (+/-5 mm about center)
Isotropic:
No problems with inhomogeneities in sources.
Validated:
Operation of the HDR 1000 Plus is described in nineteen publications clearly demonstrating the superior performance of the HDR 1000 Plus Well Chamber.
Versatile:
Can be used with any standard electrometer.
Click Here to Download a Printable Information Sheet. (.PDF format)