P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax: (440) 729-8238
Radiation Therapy
3-D Water Phantom Dosimetry
ADCL Calibrations
Area Monitors
Barometers-Thermometers-Accessories
Block-Mold Room
CT Electron Density Phantom
Digital Portal Imaging
Electrometers
HDR-LDR Accessories
IMRT QA Equipment
Ion Chambers
Linac Daily Output QA Devices
Patient Dose Verification System
Radiation Survey Meters
Room Lasers
Sensitometers-Desensitometers
TG-51 Water Phantom
Triax Cable Reels
Triax Extension Cables
Water Equivalent Phantoms
Diagnostic Radiology
Calibration Services
Diagnostic Test Tools
Multi Function Meters
Radiation Protection-Monitoring
Test Patterns-Accessories
Test Phantoms
Radiation Safety-Homeland Security
Detectors
Digital Portal Imaging
Gate Monitors
Handheld Survey Meters
Personal Dosimeters
Portal Monitor
Radiation Simulation-Training
Response Kits
Waste Monitors
Nuclear Medicine
Dose Calibrators
Lead Shielding
Thyroid Uptake System
IMRT QA Equipment :
PTW seven29 2D-ARRAY Ion Chamber Matrix
2D-ARRAY
seven29
Detector matrix with 729 ionization chambers for quality control and dosimetry in radiation therapy
Features:
Provides a (27 x 27) ion chamber matrix resulting in an effective measuring field of 27 cm x 27 cm
Can be used in a slab phantom due to the flat design
Records dynamic and static fields in just one run
Displays absorbed dose or dose rate
Avoids detector ageing effects by utilizing ion hambers
The 2D-ARRAY
seven29
is a new concept of an ion chamber matrix in a plane for IMRT verification and quality control in radiation therapy. Utilizing ion chambers avoids radiation defects, the major drawback of solid-state detectors. The vented planeparallel ion chambers are 5 mm x 5 mm x 5 mm in size, and the center-to-center spacing is 10 mm. In total there are located 729 chambers in a matrix 27 x 27, providing a maximum field size of 27 cm x 27 cm. The surrounding material is acrylic (PMMA).
The 2D-ARRAY
seven29
can be used for the dose verification of IMRT beams by using the VeriSoft software, and it can be used for routine quality control of high-energy photon and electron beams by using the MultiCheck software. MLC leaf positioning can also be checked by the 2D-ARRAY
seven29
.
The package includes an interface for fast data acquisition. The display cycle can be set between 400 and 1000 ms and the MatrixScan software acquires dose and dose rate data, displays 3D graphics and transfers the acquired data to VeriSoft, MultiCheck or MEPHYSTO mc2 software.
Click Here to Download a Printable Information Sheet. (.PDF format)