P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax:     (440) 729-8238

Radiation Therapy
   3-D Water Phantom Dosimetry
   ADCL Calibrations
   Area Monitors
   Barometers-Thermometers-Accessories
   Block-Mold Room
   CT Electron Density Phantom
   Digital Portal Imaging
   Electrometers
   HDR-LDR Accessories
   IMRT QA Equipment
   Ion Chambers
   Linac Daily Output QA Devices
   Patient Dose Verification System
   Radiation Survey Meters
   Room Lasers
   Sensitometers-Desensitometers
   TG-51 Water Phantom
   Triax Cable Reels
   Triax Extension Cables
   Water Equivalent Phantoms
Diagnostic Radiology
   Calibration Services
   Diagnostic Test Tools
   Multi Function Meters
   Radiation Protection-Monitoring
   Test Patterns-Accessories
   Test Phantoms
Radiation Safety-Homeland Security
   Detectors
   Digital Portal Imaging
   Gate Monitors
   Handheld Survey Meters
   Personal Dosimeters
   Portal Monitor
   Radiation Simulation-Training
   Response Kits
   Waste Monitors
Nuclear Medicine
   Dose Calibrators
   Lead Shielding
   Thyroid Uptake System


IMRT QA Equipment : PTW seven29 2D-ARRAY Ion Chamber Matrix
PTW seven29 2D-ARRAY Ion Chamber Matrix 2D-ARRAY seven29

Detector matrix with 729 ionization chambers for quality control and dosimetry in radiation therapy

Features:
  • Provides a (27 x 27) ion chamber matrix resulting in an effective measuring field of 27 cm x 27 cm
  • Can be used in a slab phantom due to the flat design
  • Records dynamic and static fields in just one run
  • Displays absorbed dose or dose rate
  • Avoids detector ageing effects by utilizing ion hambers
  • The 2D-ARRAY seven29 is a new concept of an ion chamber matrix in a plane for IMRT verification and quality control in radiation therapy. Utilizing ion chambers avoids radiation defects, the major drawback of solid-state detectors. The vented planeparallel ion chambers are 5 mm x 5 mm x 5 mm in size, and the center-to-center spacing is 10 mm. In total there are located 729 chambers in a matrix 27 x 27, providing a maximum field size of 27 cm x 27 cm. The surrounding material is acrylic (PMMA).

    The 2D-ARRAY seven29 can be used for the dose verification of IMRT beams by using the VeriSoft software, and it can be used for routine quality control of high-energy photon and electron beams by using the MultiCheck software. MLC leaf positioning can also be checked by the 2D-ARRAY seven29.

    The package includes an interface for fast data acquisition. The display cycle can be set between 400 and 1000 ms and the MatrixScan software acquires dose and dose rate data, displays 3D graphics and transfers the acquired data to VeriSoft, MultiCheck or MEPHYSTO mc2 software.

    Click Here to Download a Printable Information Sheet. (.PDF format)
     
    PH 1-800-795-5226 FAX 440-729-8238
    P.O. Box 666 Chesterland, OH 44026


    Site created & maintained by
    Tux Studios.Com

    © LACO Online, Chesterland, Ohio



     Other Products

     UNIDOS® E
    More Info

     

     Backpointer Patient Alignment Lasers
    More Info

     

     Model 9-3 Five Range Ion Chamber
    More Info