P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax: (440) 729-8238
Radiation Therapy
3-D Water Phantom Dosimetry
Waste Monitors
ADCL Calibrations
Area Monitors
Barometers-Thermometers-Accessories
Block-Mold Room
CT Electron Density Phantom
Digital Portal Imaging
Electrometers
HDR-LDR Accessories
IMRT QA Equipment
Ion Chambers
Linac Daily Output QA Devices
Patient Dose Verification System
Radiation Survey Meters
Room Lasers
Sensitometers-Desensitometers
Superficial and Orthovoltage Radiotherapy Equipment
TG-51 Water Phantom
Triax Cable Reels
Triax Extension Cables
Water Equivalent Phantoms
Diagnostic Radiology
Calibration Services
Multi Function Meters
Radiation Protection-Monitoring
Test Patterns-Accessories
Test Phantoms
Radiation Safety-Homeland Security
Detectors
Digital Portal Imaging
Gate Monitors
Handheld Survey Meters
Personal Dosimeters
Portal Monitor
Radiation Simulation-Training
Response Kits
Nuclear Medicine
Dose Calibrators
Lead Shielding
Thyroid Uptake System
Ion Chambers :
Semi-Flex Chamber
The semiflex chambers are designed for therapy dosimetry, mainly for dose distribution measurements in motorized water phantoms. They have a short stem for mounting and a flexible connection cable. The nominal useful energy range is from 30 keV to 50 MeV photons.
The wall material is graphite with a protective acrylic cover. The guard ring borders the measuring volume. An acrylic build-up cap for in-air measurement in Co-60 beams is included with each chamber, as well as a calibration certificate for calibration in absorbed dose to water or in air kerma. Air density correction is required for each measurement, and a radioactive check device is available as an option. Both chambers are shaped cylindrically with an inner diameter of 5.5 mm; they differ only in the length of the measuring volume. The 0.125 cm³ chamber is ideal for 3D dosimetry in a water phantom, since the measuring volume is approximately spherical resulting in a flat angular response over an angle of ± 160° and a uniform spatial resolution along all three axes of a water phantom.
Features:
Waterproof thimble chambers for measuring high-energy photon and electron radiation in air, water and phantom material
Vented sensitive volumes of 0.125 cm³ and 0.3 cm³
Flat energy response within a wide energy range
Click Here to Download a Printable Information Sheet. (.PDF format)
PH 1-800-795-5226
FAX 440-729-8238
P.O. Box 666 Chesterland, OH 44026
Site created & maintained by
Tux Studios.Com
© LACO Online, Chesterland, Ohio
Advanced Search
Other Products
Model 19 MicroR
More Info
PinPoint® Chambers
More Info
Model 3 with Model 44-3 Gamma Scintillator
More Info