P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax:     (440) 729-8238

Radiation Therapy
   3-D Water Phantom Dosimetry
   Waste Monitors
   ADCL Calibrations
   Area Monitors
   Barometers-Thermometers-Accessories
   Block-Mold Room
   CT Electron Density Phantom
   Digital Portal Imaging
   Electrometers
   HDR-LDR Accessories
   IMRT QA Equipment
   Ion Chambers
   Linac Daily Output QA Devices
   Patient Dose Verification System
   Radiation Survey Meters
   Room Lasers
   Sensitometers-Desensitometers
   Superficial and Orthovoltage Radiotherapy Equipment
   TG-51 Water Phantom
   Triax Cable Reels
   Triax Extension Cables
   Water Equivalent Phantoms
Diagnostic Radiology
   Calibration Services
   Multi Function Meters
   Radiation Protection-Monitoring
   Test Patterns-Accessories
   Test Phantoms
Radiation Safety-Homeland Security
   Detectors
   Digital Portal Imaging
   Gate Monitors
   Handheld Survey Meters
   Personal Dosimeters
   Portal Monitor
   Radiation Simulation-Training
   Response Kits
Nuclear Medicine
   Dose Calibrators
   Lead Shielding
   Thyroid Uptake System


Ion Chambers : Roos® Chamber
Roos® Chamber The Roos electron chamber, developed in cooperation with Dr. Roos, PTB-Braunschweig (National Laboratory of Germany), is used as a reference electron chamber. It is recommended by the IAEA for high precision electron dosimetry in radiation therapy. The chamber has a 4 mm wide guard ring to exclude any perturbation effect even at low electron energies. The polarity effect is negligible (< 0.5 % at 10 MeV).

The energy response is only influenced by the stopping power ratios. The chamber is waterproof for absolute dose and depth dose measurements in a water phantom. The acrylic entrance window has a thickness of 1 mm. The nominal useful energy range is from 2 MeV to 45 MeV. A calibration certificate with a Co-60 calibration factor given in absorbed dose to water is included. Air density correction is required for each measurement. A radioactive check device with adapter is available as an option. The chamber cable length is 1.08 m.

Features:
  • Precision plane-parallel reference chamber for absolute dosimetry of high-energy electron radiation
  • Vented sensitive volume of 0.35 cm³
  • Perturbation-free design and minimal polarity effect
  • Suitable for use in water and in solid state phantoms


  • Click Here to Download a Printable Information Sheet. (.PDF format)
     
    PH 1-800-795-5226 FAX 440-729-8238
    P.O. Box 666 Chesterland, OH 44026


    Site created & maintained by
    Tux Studios.Com

    © LACO Online, Chesterland, Ohio



     Other Products

     Sun Nuclear Daily QA 3 TM Daily QA Accelerated
    More Info

     

     LA48 Array
    More Info

     

     Atomlab 930
    More Info