P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax:     (440) 729-8238

Radiation Therapy
   3-D Water Phantom Dosimetry
   ADCL Calibrations
   Area Monitors
   Barometers-Thermometers-Accessories
   Block-Mold Room
   CT Electron Density Phantom
   Digital Portal Imaging
   Electrometers
   HDR-LDR Accessories
   IMRT QA Equipment
   Ion Chambers
   Linac Daily Output QA Devices
   Patient Dose Verification System
   Radiation Survey Meters
   Room Lasers
   Sensitometers-Desensitometers
   TG-51 Water Phantom
   Triax Cable Reels
   Triax Extension Cables
   Water Equivalent Phantoms
Diagnostic Radiology
   Calibration Services
   Diagnostic Test Tools
   Multi Function Meters
   Radiation Protection-Monitoring
   Test Patterns-Accessories
   Test Phantoms
Radiation Safety-Homeland Security
   Detectors
   Digital Portal Imaging
   Gate Monitors
   Handheld Survey Meters
   Personal Dosimeters
   Portal Monitor
   Radiation Simulation-Training
   Response Kits
   Waste Monitors
Nuclear Medicine
   Dose Calibrators
   Lead Shielding
   Thyroid Uptake System


Ion Chambers : PinPoint® Chambers
PinPoint® Chambers PinPoint® Chambers
0.015 cm³, 0.03cm³, 0.016cm³
Type 31014, 31015, 31016

The waterproof PinPoint chambers have been specially designed for dose distribution measurements in a motorized water phantom for characterization of LINAC radiation fields where superior spatial resolution is desired. The PinPoint chambers are ideally suited for measurements of high-energy photon beams with a field size from 2 x 2 cm² to 30 x 30 cm².

PinPoint chamber 31014 features a measuring volume with only 2 mm diameter. PinPoint chamber 31015 is a "longer" version of type 31014, featuring the same diameter but twice the measuring volume.

PinPoint 3D chamber model 31016 has a measuring volume with 2.9 mm diameter but shows a flat angular response, since the measuring volume is approximately spherical.

The sensitive volumes are vented. The wall materials are graphite with protective acrylic covers. All chambers are fully guarded up to the measuring volume. The nominal energy range is Co-60 up to 50 MV photons. The chambers have a short stem for mounting and a flexible connection cable. They can be supplied with different connector types.

Features:
  • High-resolution versions 31014 and 31015 with sensitive volumes of 0.015 cm³ and 0.03 cm³, respectively
  • 3D version 31016 for spherical angular response
  • Suitable for dose scanning in radiotherapy photon beams with a superior spatial resolution
  • Suitable for use in water


  • Click Here to Download a Printable Information Sheet. (.PDF format)
     
    PH 1-800-795-5226 FAX 440-729-8238
    P.O. Box 666 Chesterland, OH 44026


    Site created & maintained by
    Tux Studios.Com

    © LACO Online, Chesterland, Ohio



     Other Products

     MOSFET 20 Dose Verification - DISCONTINUED
    More Info

     

     Reference Digital Handheld Thermometers
    More Info

     

     PROFILER 2
    More Info