Radiation Therapy
   3-D Water Phantom Dosimetry
   ADCL Calibrations
   Area Monitors
   Barometers-Thermometers-Accessories
   Block-Mold Room
   CT Electron Density Phantom
   Digital Portal Imaging
   Electrometers
   HDR-LDR Accessories
   IMRT QA Equipment
   Ion Chambers
   Linac Daily Output QA Devices
   Patient Dose Verification System
   Radiation Survey Meters
   Room Lasers
   Sensitometers-Desensitometers
   TG-51 Water Phantom
   Triax Cable Reels
   Triax Extension Cables
   Water Equivalent Phantoms
Diagnostic Radiology
   Calibration Services
   Diagnostic Test Tools
   Multi Function Meters
   Radiation Protection-Monitoring
   Test Patterns-Accessories
   Test Phantoms
Radiation Safety-Homeland Security
   Detectors
   Digital Portal Imaging
   Gate Monitors
   Handheld Survey Meters
   Personal Dosimeters
   Portal Monitor
   Radiation Simulation-Training
   Response Kits
   Waste Monitors
Nuclear Medicine
   Dose Calibrators
   Lead Shielding
   Thyroid Uptake System


Electrometers : Model 35040 Electrometer
Model 35040 Electrometer Advanced Therapy Dosimeter
Model 35040

Introduction

The 35040 Advanced Therapy Dosimeter is a reference grade instrument used to measure the charge and current from ion chambers in Radiation Therapy, and provides bias voltage for all commonly used chambers. The ATD large clear display offers direct readings of charge, current, time and radiation units over a wide range. The user can customize the display for basic use or for specialized applications such as brachytherapy. The Advanced Therapy Dosimeter exceeds the recommendations of calibration laboratories for leakage, linearity, and stability by a wide margin. This instrument raises the standard of Radiation Therapy measurements.

The 35040 Advanced Therapy Dosimeter, provides the long-term stability and accuracy demanded for calibrations, quality assurance programs, and protocols in Radiation Therapy.

Applications
Radiation Therapy requires great accuracy in the measurement of dose and dose rate values associated with linear accelerators and radioactive sources. The Model 35040 Advanced Therapy Dosimeter provides the long-term stability and accuracy demanded for calibrations, quality assurance programs, and protocols in Radiation Therapy. A unique electrometer design provides more accuracy than high meg resistor or capacitor feedback electrometers.

The 35040 Advanced Therapy Dosimeter is fully stable within five minutes. In battery operation or using AC Line, the ATD measures dose and effective exposure time in a single exposure, thus eliminating the need for multiple exposures for Cobalt 60 and brachytherapy measurements. Front panel controls select ion chamber calibration factors, facilitate entry of temperature and pressure values for air density correction, allow bias voltage selection, threshold level, timer control, and choice of display screens. The user-customized display screens can simultaneously show dose, exposure time, dose rate, effective exposure time, average current/rate, accumulated charge/dose, bias voltage, leakage, and other important information that ensures the validity of the instrument.

The customization software allows design of 16 screens that display conditions, parameters, values and text. Up to 32 chambers factors, 11 bias voltages can be programmed. It is PC compatible and connects via a RS-232 cable.

  • Now with timer function and wider dynamic range
  • Ultra long-term stability error of approximately 0.1% per five years.
  • Virtually removes effects of system leakage during measurement. Uncorrected leakage <10 fA over temperature range
  • Eleven user-defined bias settings from -500 V to +500 V
  • Read out in C, A, R, Gy, Sv, Bq, and more


  • Features
  • Wide measurement range, up to 1,000 µA and 19.999 mC for HDR Brachytherapy applications
  • Automatic reset and hold of measured valued between exposures
  • Front panel adjustment of exposure threshold and user disable of threshold to permit manual operation
  • Thirty-two ion chamber calibration factors
  • Automatic power-down after user-specified time period, when operating from battery supply
  • Annunciators warn of low battery, low bias, and operational errors
  • Large capacity battery provides eight hours of continuous operation; fast recharge in less than three hours, even during operation
  • AC line operation over the range 100 to 240 VAC and 47 to 63 Hz without operator intervention
  • Charge and current calibration factors entered by calibration laboratories at user’s option
  • Front and rear panel ion chamber connections
  • Optional carrying case (Model 37780)


  • Click Here to Download a Printable Information Sheet. (.pdf format)
     
    PH 1-800-795-5226 FAX 440-729-8238
    P.O. Box 666 Chesterland, OH 44026


    Site created & maintained by
    Tux Studios.Com

    © LACO Online, Chesterland, Ohio



     Other Products

     Model 3A Alarming Survey Meter
    More Info

     

     Farmer Chamber
    More Info

     

     VIDAR Dosimetry PRO
    More Info