P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax: (440) 729-8238
Radiation Therapy
3-D Water Phantom Dosimetry
ADCL Calibrations
Area Monitors
Barometers-Thermometers-Accessories
Block-Mold Room
CT Electron Density Phantom
Digital Portal Imaging
Electrometers
HDR-LDR Accessories
IMRT QA Equipment
Ion Chambers
Linac Daily Output QA Devices
Patient Dose Verification System
Radiation Survey Meters
Room Lasers
Sensitometers-Desensitometers
TG-51 Water Phantom
Triax Cable Reels
Triax Extension Cables
Water Equivalent Phantoms
Diagnostic Radiology
Calibration Services
Diagnostic Test Tools
Multi Function Meters
Radiation Protection-Monitoring
Test Patterns-Accessories
Test Phantoms
Radiation Safety-Homeland Security
Detectors
Digital Portal Imaging
Gate Monitors
Handheld Survey Meters
Personal Dosimeters
Portal Monitor
Radiation Simulation-Training
Response Kits
Waste Monitors
Nuclear Medicine
Dose Calibrators
Lead Shielding
Thyroid Uptake System
Linac Daily Output QA Devices :
Tracker™ Model 90100
Introduction
The TRACKER™ Therapy Beam Evaluation System, Model 90100, is a quality assurance system that measures therapy radiation sources, including dose and dose rate, enabling user calculation of beam constancy, flatness, and symmetry. The system consists of the Model 35300A Detector and Model 35360A Display.
The Model 35300A TRACKER detector array incorporates four orthogonally-placed ion chambers on a 10cm radius from a fifth isocentrally-located ion chamber, allowing ratio-to-center dose measurement. Each ion chamber, which is identical to the others and vented to the atmosphere, is a circular, parallel-plate configuration and is fully guarded for low leakage. An overlay indicates ion chamber locations for alignment with a therapy beam light field system. The Model 35360A TRACKER display contains five electrometers and is characterized by a microprocessor controlled, 4-line by 20-character Vacuum Fluorescent Display (VFD) that enables excellent readability of dose and dose rate measurements in virtually any lighting condition.
APPLICATION
The TRACKER Therapy Beam Evaluation System performs quality assurance tests for linear accelerators, Cobalt 60, and therapeutic x-ray equipment. The system's quick setup and operational ease make it ideal for daily checks of beam constancy, symmetry, and flatness.
A five-channel electrometer enables measurement of dose or dose rate in either absolute or ratio to center. Dose measurement values may be displayed in units of R, rad, Sv, or Gy. Dose rate measurement values may be displayed in units of R/min, rad/min, Sv/min, or Gy/min.
The TRACKER System may be operated from either AC line power or from its high capacity internal battery. The battery is charged automatically when the unit is connected to AC line power, either during use or when idle.
Consulting physicists and service engineers will appreciate the TRACKER System's portability. An optional carrying case eases transport and storage. Other optional accessoriesinclude buildup plates of various thickness' and materials and a buildup retaining hardware kit.
Features
Measurement values from peripheral ion chambers displayed in either absolute dose measurement units or as percentage of center ion chamber's measurement value.
Microprocessor-controlled, 4-line by 20-character VFD corrects for air density and displays measurement results directly in user's choice of radiological units.
Precision five channel electrometer provides +/-0.05% linearity.
High performance rechargeable system allows eight hours of continuous operation from a three-hour charge; low battery annunciator indicates when <30 minutes of operation remains.
Levels of internal 300V electronic bias supply and rechargeable battery supply are continuously monitored
Annunciators indicate abnormal bias or low battery voltage
Click Here to Download a Printable Information Sheet. (.pdf format)
PH 1-800-795-5226
FAX 440-729-8238
P.O. Box 666 Chesterland, OH 44026
Site created & maintained by
Tux Studios.Com
© LACO Online, Chesterland, Ohio
Advanced Search
Other Products
Atomlab 930
More Info
Veridose
More Info
Ludlum Neutron Detector
More Info