P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax:     (440) 729-8238

Radiation Therapy
   3-D Water Phantom Dosimetry
   ADCL Calibrations
   Area Monitors
   Barometers-Thermometers-Accessories
   Block-Mold Room
   CT Electron Density Phantom
   Digital Portal Imaging
   Electrometers
   HDR-LDR Accessories
   IMRT QA Equipment
   Ion Chambers
   Linac Daily Output QA Devices
   Patient Dose Verification System
   Radiation Survey Meters
   Room Lasers
   Sensitometers-Desensitometers
   TG-51 Water Phantom
   Triax Cable Reels
   Triax Extension Cables
   Water Equivalent Phantoms
Diagnostic Radiology
   Calibration Services
   Diagnostic Test Tools
   Multi Function Meters
   Radiation Protection-Monitoring
   Test Patterns-Accessories
   Test Phantoms
Radiation Safety-Homeland Security
   Detectors
   Digital Portal Imaging
   Gate Monitors
   Handheld Survey Meters
   Personal Dosimeters
   Portal Monitor
   Radiation Simulation-Training
   Response Kits
   Waste Monitors
Nuclear Medicine
   Dose Calibrators
   Lead Shielding
   Thyroid Uptake System


Area Monitors : Model 375 Area Monitor with Model 271 Remote and 60 ft cable
Model 375 Area Monitor with Model 271 Remote and 60 ft cable Model 375 Area Monitor with
Model 271 Remote and 60 ft cable

* LED Digital Display
* Low and High Alarm Indicators
* Programmable Alarm Indicator
* Built-In Energy Compensated G-M
* Detector Fail Indicator
* Battery Backup
* Data Output/RS-232
* Total Counting Range from 0.1 mR/hr - 1R/hr

Model 375 Area Monitor
INDICATED USE: Area monitoring
COMPATIBLE DETECTORS: G-M, proportional, scintillation, and neutron
DISPLAY: 4 digit LED display with 0.8"(2cm) character height
DISPLAY RANGE: 000.0 - 9999
DISPLAY UNITS: Can be made to display in microR/hr, mR/hr, R/hr, microSv/h, mSv/h, Sv/h, microrem/hr, mrem/hr, rem/hr, cpm, cps, and others
LINEARITY: Reading within plus or minus 10% of true value with detector connected
RESPONSE: Typically 3 seconds from 10% to 90% of final reading
STATUS: (green light) Indicates the instrument is functioning properly
LOW ALARM: Indicated by a yellow light and slow beep (1 per second) audible tone (can be set at any point from 0.0 - 9999)
HIGH ALARM: Indicated by a red light and fast beep (4 per second) audible tone (can be set at any point from 0.0 - 9999)
NOTE:Audible indicators can be configured as a single beep if desired.
DET FAIL: (red light and audible tone; greater than 68 Db at 2 feet) Indicates detector overload, no count from detector, or instrument failure
LOW BAT: (yellow) Indicates less than 2 hours of battery power remaining
CONNECTOR: Series "C" (others available )
CALIBRATION CONTROLS: Accessible from front of instrument (protective cover provided )
HIGH VOLTAGE: Adjustable from 200 - 2500 volts
THRESHOLD: Adjustable from 2 - 100 mV
DEAD TIME: Adjustable to compensate for dead time of the detector and electronics (can be read on the display)
OVERLOAD: Senses detector saturation (indicated by display reading"-OL-")
OVERRANGE: Indicates the radiation field being measured has exceeded the counting range of the instrument (indicated by display reading "----")
DATA OUTPUT: 9 pin connector providing 5 decade log output, RS-232 output, signal ground connection, FAIL and Alarm signals (current sink), and direct connection to battery and ground
REMOTE(optional): Model 271, or Model 272 remote units
POWER: 95 - 135 VAC (178 - 240 VAC available), 50 - 60 Hz single phase (less than 100 mA), 6 volt sealed lead acid rechargeable battery (built in)
BATTERY LIFE: Typically 48 hours in non-alarm condition, 12 hours in alarm condition
BATTERY CHARGER: Battery is continuously trickle charged when instrument is connected to line power and turned on
CONSTRUCTION: Aluminum housing with ivory polyurethane enamel paint
TEMPERATURE RANGE: -4° F(-20° C) to 122° F(50° C)
May be certified for operation from -40° F(-40° C) to 150° F(65° C)
SIZE: 7.4" (18.7 cm)H X 9.7" (24.6 cm)W X 2.5" (6.4 cm)L
WEIGHT: 6.5 lbs (2.3 kg)

Model 271 Remote
INDICATED USE: Remote display for Model 375 Area Monitor
STATUS: (green light) Indicates the instrument is functioning properly
HIGH ALARM: (red LED) Indicates that the radiation level exceeds the high alarm point
DET FAIL: (red LED) Indicates detector overload, no count from detector, or instrument failure
AUDIO: Unimorph type with ON/OFF switch(greater than 68 dB at 2 feet)
POWER: Provided by Model 375 (20 foot cable included)
CONSTRUCTION: Aluminum housing with ivory polyurethane enamel paint
TEMPERATURE RANGE: -4° F(-20° C) to 122° F(50° C)
May be certified for operation from -40° F(-40° C) to 150° F(65° C)
SIZE: 7" (17.8 cm)H X 6" (15.2 cm)W X 2" (5.1 cm)L
WEIGHT: 1.5 lbs (0.7 kg)

Click Here to Download a Printable Information Sheet. (.PDF format)
 
PH 1-800-795-5226 FAX 440-729-8238
P.O. Box 666 Chesterland, OH 44026


Site created & maintained by
Tux Studios.Com

© LACO Online, Chesterland, Ohio



 Other Products

 Astor Patient Alignment Lasers
More Info

 

 Ludlum Model 44-88 Alpha, Beta, Gamma GM Detector
More Info

 

 Model 3A Alarming Survey Meter
More Info