P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax: (440) 729-8238
Radiation Therapy
3-D Water Phantom Dosimetry
ADCL Calibrations
Area Monitors
Barometers-Thermometers-Accessories
Block-Mold Room
CT Electron Density Phantom
Digital Portal Imaging
Electrometers
HDR-LDR Accessories
IMRT QA Equipment
Ion Chambers
Linac Daily Output QA Devices
Patient Dose Verification System
Radiation Survey Meters
Room Lasers
Sensitometers-Desensitometers
TG-51 Water Phantom
Triax Cable Reels
Triax Extension Cables
Water Equivalent Phantoms
Diagnostic Radiology
Calibration Services
Diagnostic Test Tools
Multi Function Meters
Radiation Protection-Monitoring
Test Patterns-Accessories
Test Phantoms
Radiation Safety-Homeland Security
Detectors
Digital Portal Imaging
Gate Monitors
Handheld Survey Meters
Personal Dosimeters
Portal Monitor
Radiation Simulation-Training
Response Kits
Waste Monitors
Nuclear Medicine
Dose Calibrators
Lead Shielding
Thyroid Uptake System
Waste Monitors :
Model 375P-336 Waste Monitor
Model 375P-336
Waste Monitor
* Plastic Scintillation Detectors
* Microprocessor Based Electronics
* Audible and Visual Alarm Indicators
System Includes:
* 1 ea. Model 375 Electronic
* 2 ea. 168 in3 (2753 cm3) Plastic Detectors with 25 ft (7.6 m) cables
* 1 ea. 10μCi Check Source
INDICATED USE:
Area Monitoring
DETECTOR:
2 ea. 168 in³ plastic scintillation detectors
DISPLAY:
4 digit LED display with 0.8" (2 cm) digits
RANGE:
0.1 - 9999 kcps
LINEARITY:
Reading within ± 10% of true value with detector connected
RESPONSE:
Typically 3 seconds from 10% - 90% of final reading
STATUS:
(green light)
instrument functioning properly
SIGMA ALARM:
Indicated by red ALARM light and audible tone(
can be set at any point from 0.0 - 9999 kcps
)
SUM ALARM:
Indicated by red ALARM light and audible tone (can be set at set at any point from 0.0 - 9999 kcps)
NOTE
:
Audible alarm indicators can be configured as a single beep if desired
DET FAIL:
(
red light and audible tone; greater than 68 dB at 2 feet
) indicates detector overload, no count from detector, or instrument failure
LOW BAT:
(
yellow
) indicates less than 2 hours of battery power remaining
OVERLOAD:
Senses detector saturation (
indicated by display reading "-OL-"
)
OVERRANGE:
Indicates radiation field being measured has exceeded counting range of instrument (
indicated by display reading "____"
)
RELAY OUTPUT:
Mains (120 or 280 VAC) output on alarm
DATA OUTPUT:
9 pin connector providing RS-232 output, signal ground connection, FAIL and ALARM signals (
current sink
), and direct connection to battery and ground
CALIBRATION CONTROLS:
Accessible from front of instrument (
protective cover provided
)
POWER:
95 - 135 VAC (
178 - 240 VAC available
), 50-60 Hz single phase (
less than 100mA
),
6 volt sealed lead-acid rechargeable battery (
built in
)
BATTERY LIFE:
Typically 48 hours in non-alarm condition; 12 hours in alarm condition
BATTERY CHARGER:
Battery is continuously trickle charged when instrument is connected to line power and turned on
CONSTRUCTION:
Aluminum housing with ivory powder coat paint
TEMPERATURE RANGE:
5°F(-15°C) to 122°F(50°C)
May be certified to operate from -40°F(-40°C) to 150°F(65°C)
SIZE:
Electronics:
10.3" (26.2 cm)H X 9.7" (24.6 cm)W X 3.3" (8.4 cm)D
Detectors (ea.):
41"(104.1 cm)H X 6.75"(17.1cm)W X 2.125(5.4 cm)D
Plastic: 28"(71.1 cm)H X 4"(10.2 cm)W X 1.5(3.8 cm)D
WEIGHT:
Electronics:
9.3 lbs (4.2 kg)
Detectors (ea.):
23.5 lbs(10.7 kg)
Optional Accessories
* 5 in diameter red alarm strobe with 50 ft (15 m) cable
* 40 Column Date/Time Printer
* Ethernet Kit
Click Here to Download a Printable Information Sheet. (.PDF format)
PH 1-800-795-5226
FAX 440-729-8238
P.O. Box 666 Chesterland, OH 44026
Site created & maintained by
Tux Studios.Com
© LACO Online, Chesterland, Ohio
Advanced Search
Other Products
MapCHECK Discontinued
More Info
Tracker™ Model 90100
More Info
CIRS Model 002HN IMRT Head and Neck Phantom
More Info