Waste Monitors : Model 375P-336 Waste Monitor

Model 375P-336 Waste Monitor

Model 375P-336

Waste Monitor

This system is very easy to operate and easy to maintain. The Model 375P-336 is used for surface contamination screening, and also for laudry and medical waste screening.

Plastic Scintillation Detectors
Microprocessor Based Electronics
Audible and Visual Alarm Indicators
System Includes:
  • 1 each Model 375 Electronic
  • 2 each 168 in3 (2753 cm3) Plastic Detectors with 25 ft (7.6 m) cables
  • 1 each 10μCi Check Source

INDICATED USE: Area Monitoring

DETECTOR: 2 ea. 168 in3 plastic scintillation detectors

DISPLAY: 4 digit LED display with 0.8" (2 cm) digits

RANGE: 0.1 - 9999 kcps

LINEARITY: Reading within ± 10% of true value with detector connected

RESPONSE: Typically 3 seconds from 10% - 90% of final reading

STATUS: (green light) instrument functioning properly

SIGMA ALARM: Indicated by red ALARM light and audible tone(can be set at any point from 0.0 - 9999 kcps)

SUM ALARM: Indicated by red ALARM light and audible tone (can be set at set at any point from 0.0 - 9999 kcps)

NOTE: Audible alarm indicators can be configured as a single beep if desired.

DET FAIL: (red light and audible tone; greater than 68 dB at 2 feet) indicates detector overload, no count from detector, or instrument failure

LOW BAT: (yellow) indicates less than 2 hours of battery power remaining

OVERLOAD: Senses detector saturation (indicated by display reading "-OL-")

OVERRANGE: Indicates radiation field being measured has exceeded counting range of instrument(indicated by display reading "____")

RELAY OUTPUT: Mains (120 or 280 VAC) output on alarm

DATA OUTPUT: 9 pin connector providing RS-232 output, signal ground connection, FAIL and ALARM signals (current sink), and direct connection to battery and ground

CALIBRATION CONTROLS: Accessible from front of instrument (protective cover provided)

POWER: 95 - 135 VAC (178 - 240 VAC available), 50-60 Hz single phase (less than 100mA), 6 volt sealed lead-acid rechargeable battery (built in)

BATTERY LIFE: Typically 48 hours in non-alarm condition; 12 hours in alarm condition

BATTERY CHARGER: Battery is continuously trickle charged when instrument is connected to line power and turned on

CONSTRUCTION: Aluminum housing with ivory powder coat paint

TEMPERATURE RANGE: 5ºF(-15ºC) to 122ºF(50ºC);
May be certified to operate from -40ºF(-40ºC) to 150ºF(65ºC)

SIZE: Electronics: 10.3"(26.2 cm) in H X 9.7"(24.6 cm) in W X 3.3"(8.4 cm) in D
Detectors (ea): 41"(104.1 cm) in H X 6.75"(17.1cm) in W X 2.125"(5.4 cm) in D
Plastic: 28"(71.1 cm) in H X 4"(10.2 cm) in W X 1.5"(3.8 cm) in D

WEIGHT: Electronics: 9.3 lbs (4.2 kg)
Detectors (ea): 23.5 lbs (10.7 kg)

Optional Accessories
  • 5 in diameter red alarm strobe with 50 ft (15 m) cable
  • 40 Column Date/Time Printer
  • Ethernet Kit