P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax:     (440) 729-8238

Radiation Therapy
   3-D Water Phantom Dosimetry
   ADCL Calibrations
   Area Monitors
   Barometers-Thermometers-Accessories
   Block-Mold Room
   CT Electron Density Phantom
   Digital Portal Imaging
   Electrometers
   HDR-LDR Accessories
   IMRT QA Equipment
   Ion Chambers
   Linac Daily Output QA Devices
   Patient Dose Verification System
   Radiation Survey Meters
   Room Lasers
   Sensitometers-Desensitometers
   TG-51 Water Phantom
   Triax Cable Reels
   Triax Extension Cables
   Water Equivalent Phantoms
Diagnostic Radiology
   Calibration Services
   Diagnostic Test Tools
   Multi Function Meters
   Radiation Protection-Monitoring
   Test Patterns-Accessories
   Test Phantoms
Radiation Safety-Homeland Security
   Detectors
   Digital Portal Imaging
   Gate Monitors
   Handheld Survey Meters
   Personal Dosimeters
   Portal Monitor
   Radiation Simulation-Training
   Response Kits
   Waste Monitors
Nuclear Medicine
   Dose Calibrators
   Lead Shielding
   Thyroid Uptake System


IMRT QA Equipment : OCTAVIUS Octagonal Phantom
OCTAVIUS Octagonal Phantom Enhances the 2D-ARRAY seven29 to a measuring system for Intensity Modulated Arc Therapy (IMAT)

Features
* Suitable for all dynamic techniques
* Time saving IMAT treatment plan verification
* Signal independent of beam direction due to most advanced ion chamber design
* One single measurement for entire IMAT plan verification
* Calibrated for absolute dose measurement, no frequent recalibration
* Data analysis with VeriSoft software1

OCTAVIUS enhances the 2D-ARRAY seven29 to a state-of-the-art measuring system for all dynamic IMRT technologies such as IMAT or tomotherapy. A CT scan of the phantom including the array must be imported into the TPS software. The TPS software recalculates the patient plan for the phantom geometry and exports the dose calculation for the layer of the array.

The phantom can be treated from all directions, exactly in the same way as a patient. VeriSoft software compares the data from the TPS with the measured data from the array. VeriSoft offers comprehensive software functions such as a Gamma Index algorithm for data analysis. The 2D-ARRAY seven29 features 27 x 27 dose points in a plane inside the phantom. Due to the cutting-edge ionization chamber design, the array can be treated from different gantry angles without angular signal dependence as known from diodes. With OCTAVIUS, IMAT plan verification does not need more time than standard IMRT plan verification with the 2D-ARRAY seven29.

1The comparison depends on the dose calculation algorithm of the TPS Monte Carlo based algorithms (e.g. AAA) give very good results.

Click Here to Download a Printable Information Sheet. (.PDF format)
 