P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax: (440) 729-8238
Radiation Therapy
3-D Water Phantom Dosimetry
ADCL Calibrations
Area Monitors
Barometers-Thermometers-Accessories
Block-Mold Room
CT Electron Density Phantom
Digital Portal Imaging
Electrometers
HDR-LDR Accessories
IMRT QA Equipment
Ion Chambers
Linac Daily Output QA Devices
Patient Dose Verification System
Radiation Survey Meters
Room Lasers
Sensitometers-Desensitometers
TG-51 Water Phantom
Triax Cable Reels
Triax Extension Cables
Water Equivalent Phantoms
Diagnostic Radiology
Calibration Services
Diagnostic Test Tools
Multi Function Meters
Radiation Protection-Monitoring
Test Patterns-Accessories
Test Phantoms
Radiation Safety-Homeland Security
Detectors
Digital Portal Imaging
Gate Monitors
Handheld Survey Meters
Personal Dosimeters
Portal Monitor
Radiation Simulation-Training
Response Kits
Waste Monitors
Nuclear Medicine
Dose Calibrators
Lead Shielding
Thyroid Uptake System
IMRT QA Equipment :
OCTAVIUS Octagonal Phantom
Enhances the 2D-ARRAY seven29 to a measuring system for Intensity Modulated Arc Therapy (IMAT)
Features
* Suitable for all dynamic techniques
* Time saving IMAT treatment plan verification
* Signal independent of beam direction due to most advanced ion chamber design
* One single measurement for entire IMAT plan verification
* Calibrated for absolute dose measurement, no frequent recalibration
* Data analysis with VeriSoft software1
OCTAVIUS enhances the 2D-ARRAY seven29 to a state-of-the-art measuring system for all dynamic IMRT technologies such as IMAT or tomotherapy. A CT scan of the phantom including the array must be imported into the TPS software. The TPS software recalculates the patient plan for the phantom geometry and exports the dose calculation for the layer of the array.
The phantom can be treated from all directions, exactly in the same way as a patient. VeriSoft software compares the data from the TPS with the measured data from the array. VeriSoft offers comprehensive software functions such as a Gamma Index algorithm for data analysis. The 2D-ARRAY seven29 features 27 x 27 dose points in a plane inside the phantom. Due to the cutting-edge ionization chamber design, the array can be treated from different gantry angles without angular signal dependence as known from diodes. With OCTAVIUS, IMAT plan verification does not need more time than standard IMRT plan verification with the 2D-ARRAY seven29.
1The comparison depends on the dose calculation algorithm of the TPS Monte Carlo based algorithms (e.g. AAA) give very good results.
Click Here to Download a Printable Information Sheet. (.PDF format)
PH 1-800-795-5226
FAX 440-729-8238
P.O. Box 666 Chesterland, OH 44026
Site created & maintained by
Tux Studios.Com
© LACO Online, Chesterland, Ohio
Advanced Search
Other Products
Cable Reel
More Info
PROFILER 2
More Info
Backpointer Patient Alignment Lasers
More Info