P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax:     (440) 729-8238

Radiation Therapy
   3-D Water Phantom Dosimetry
   Waste Monitors
   ADCL Calibrations
   Area Monitors
   Barometers-Thermometers-Accessories
   Block-Mold Room
   CT Electron Density Phantom
   Digital Portal Imaging
   Electrometers
   HDR-LDR Accessories
   IMRT QA Equipment
   Ion Chambers
   Linac Daily Output QA Devices
   Patient Dose Verification System
   Radiation Survey Meters
   Room Lasers
   Sensitometers-Desensitometers
   Superficial and Orthovoltage Radiotherapy Equipment
   TG-51 Water Phantom
   Triax Cable Reels
   Triax Extension Cables
   Water Equivalent Phantoms
Diagnostic Radiology
   Calibration Services
   Multi Function Meters
   Radiation Protection-Monitoring
   Test Patterns-Accessories
   Test Phantoms
Radiation Safety-Homeland Security
   Detectors
   Digital Portal Imaging
   Gate Monitors
   Handheld Survey Meters
   Personal Dosimeters
   Portal Monitor
   Radiation Simulation-Training
   Response Kits
Nuclear Medicine
   Dose Calibrators
   Lead Shielding
   Thyroid Uptake System


Patient Dose Verification System : Veridose Solid-State Diode Detectors
Veridose Solid-State Diode Detectors

 Veridose Solid-State Diode Detectors

 •Designed to provide superior response, reliability, and performance
•Long-lifetime diodes. Tested to 2 x 106 cGy in a high-energy electron beam, the most damaging radiation
•Very low dose rate and temperature dependence
•Hemispherical shape improves isotropic response and reduces angular and field-size dependencies

Introduction
Using the VeriDose Patient Dose Monitor Quality Control (PDMQC)
System or the VeriDose V Patient Dose Monitor in conjunction with
VeriDose Solid-State Diode Detectors, you can verify the given dose
quickly and accurately during treatment, thus avoiding potential
misadministration of radiation.

Applications
VeriDose Solid-State Diode Detectors are solid-state silicon-based
radiation detectors that utilize a p-n junction. These rugged diodes are
encased within a biocompatible polystyrene material. A low noise
coaxial cable is used to connect the diode to an electrometer. When
attached to an electrometer, these diodes provide enhanced sensitivity
and instantaneous response time.

Features
• Waterproof design with appropriate buildup for all clinical photon and electron energies
• Flat bottom permits secure, easy placement on the patient
• Color-coded for ease of identification
• Dose rate independent
• Responds to photons and electrons
• Responds to dose rates of 1.0 to 1000 cGy/min
• Can be used on continuous (60Co) x-ray beams, pulsed (linear-accelerator) x-ray beams, and electron beams
• Optimized for use with all Nuclear Associates’ Patient Dose Monitors and high-quality medical-grade ionization chamber electrometers
• All diodes are supplied with a non-crimp repairable cable with a coax BNC connector



Click Here to Download a Printable Information Sheet. (.pdf format)
 
PH 1-800-795-5226 FAX 440-729-8238
P.O. Box 666 Chesterland, OH 44026


Site created & maintained by
Tux Studios.Com

© LACO Online, Chesterland, Ohio



 Other Products

 Unfors Xi Platinum edition
More Info

 

 045 Brachy Phantom
More Info

 

 Model 14CRK Response Kit
More Info