P.O. Box 666
Chesterland, OH 44026
Phone: (800) 795-5226
Fax: (440) 729-8238
Radiation Therapy
3-D Water Phantom Dosimetry
Waste Monitors
ADCL Calibrations
Area Monitors
Barometers-Thermometers-Accessories
Block-Mold Room
CT Electron Density Phantom
Digital Portal Imaging
Electrometers
HDR-LDR Accessories
IMRT QA Equipment
Ion Chambers
Linac Daily Output QA Devices
Patient Dose Verification System
Radiation Survey Meters
Room Lasers
Sensitometers-Desensitometers
Superficial and Orthovoltage Radiotherapy Equipment
TG-51 Water Phantom
Triax Cable Reels
Triax Extension Cables
Water Equivalent Phantoms
Diagnostic Radiology
Calibration Services
Multi Function Meters
Radiation Protection-Monitoring
Test Patterns-Accessories
Test Phantoms
Radiation Safety-Homeland Security
Detectors
Digital Portal Imaging
Gate Monitors
Handheld Survey Meters
Personal Dosimeters
Portal Monitor
Radiation Simulation-Training
Response Kits
Nuclear Medicine
Dose Calibrators
Lead Shielding
Thyroid Uptake System
Barometers-Thermometers-Accessories :
Reference Digital Handheld Thermometers
Digital Handheld Thermometer with Thermocouple
This contact thermometer offers fast response and laboratory accuracy (0.05% + 0.3 C) in a rugged, handheld test tool.
Product Highlights
* A high quality, high performance, singlechannel Digital Thermocouple Thermometer with 1°C or 0.1°C (1° For 0.2° F) resolution
* Resolution applies to entire measurement range of instruments
* Functions include selectable readout in °C or °F, easily converted with the push of a button
* Self-test and HOLD Mode, which freezes a reading for convenient viewing, then releases it for continued measurements
* Sleep mode increases battery life; typical 1000-hour battery life
* Battery door allows easy battery replacement without breaking the calibration seal
* Accepts J- or K-Type Thermocouples
* Single Thermocouple Input
* Three (3) year manufacturer’s warranty
Each Unit Includes
* Holster
* One beaded probe thermocouple for general purpose applications:
- Model 80PK-1
- A basic thermocouple for good accuracy and fast response.
- K-type thermocouple
- Measurement range: -40°C to 260°C
- Not suitable for immersion
Click Here to Download a Printable Information Sheet. (.pdf format)
PH 1-800-795-5226
FAX 440-729-8238
P.O. Box 666 Chesterland, OH 44026
Site created & maintained by
Tux Studios.Com
© LACO Online, Chesterland, Ohio
Advanced Search
Other Products
Atlantic Nuclear Mobile Radiation Shields
More Info
In-vivo Semi-Conductors
More Info
Model 14-C Survey Meter
More Info