Personal Dosimeters : Ludum Model 23 Mrem Electronic Personal Dosimeter

Ludum Model 23 Mrem Electronic Personal Dosimeter

mrem Electronic Personal Dosimeter

Lightweight, Compact, Pen-Sized Dosimeter

Ideal for the measurement and general monitoring of gamma and X-ray radiation in medical and laboratory environments, as well as any controlled or restricted area where personal radiation monitoring is required or desired.

  • Low weight and slim design
  • X-ray and gamma radiation monitoring
  • Audible alarm
  • 600 record data logging option available
Introduction:

The Ludlum Model 23 Mrem Electronic Personal Dosimeter is a compact and lightweight pen-type personal dosimeter. It is ideal for the measurement and general monitoring of gamma and X-ray radiation in medical and laboratory environments, as well as any controlled or restricted area where personal radiation monitoring is required or desired.

The Ludlum Model 23 unit is sensitive to a wide range of energies from 35 keV to 3 MeV. Dose, Dose Equivalent Rate, and alarm values are easily seen on the four-digit LCD screen. An audible alarm is activated if the dose or dose rate exceeds the pre-set value of the dosimeter. The alarm set points are adjustable from the face of the Electronic Personal Dosimeter (EPD) unit.

Warning: this dosimeter may not measure pulsed radiation accurately.

For users with multiple EPD units the optional Ludlum Model 23 Mrem Reader/Software Kit can be used to quickly take data directly from the dosimeter via infrared communication to the user’s PC. The software also allows the user to set or change alarm set points quickly.

  • Compact and Lightweight
  • Audible Alarm with Adjustable Set Points
  • Transfer Data to PC with Optional Reader/Software Kit
  • Measure and Monitor X-Rays and Gamma Rays
Indicated Use:
Personnel Dosimetry Monitoring
Dose & Dose Rate Measurement Display Range:
0.1 mrem to 99.99 rem
0.1 mrem/hr to 99.99 rem/hr
Accumulated dose data is automatically deleted when Ludlum Model 23 EPD is switched "On".
Detector:
Silicon Semiconductor
Radiation Detected:
gamma & X-ray
(35 keV to 3 MeV)
Display:
4 digit LCD, with dose rate, low battery, overflow
Accuracy/Linearity:
m ± 10% from 1.0 mrem to 99.99 rem (137Cs)
Alarm Output:
low, medium, high user-adjustable volume, and OFF
Alarm Volume:
Approximately 60 dB
Sensitivity:
Approximately 20 cpm/µR/hr (137Cs gamma)
Data Logging:
600 records (optional IR reader required for PC data transmission)
Environment:
-10 to 40ºC (14 to 104ºF), ≤ 90% relative humidity (non-condensing)
Power:
One coin lithium battery (CR2450)
Battery life:
Typically one month at eight hours per day in non-alarm status
Size:
4.3 x 1.8 x. 0.5 in (H x W x D) without clip
Weight:
2 oz.